Name |
Meaning |
||||||
|
AC input |
|||||||
|
Network connection |
3P+N+PE (3P+PEN) |
||||||
|
Input voltage, V AC |
400 ± 10% |
||||||
|
Incoming current, A |
DC (without AC ports) |
DC +T1 |
DC +T2 |
DC +T1+T2 |
|||
|
397 |
428 |
430 |
462 |
||||
|
Input power, kW |
DC (without AC ports) |
DC +T1 |
DC +T2 |
DC +T1+T2 |
|||
|
259 |
266 |
281 |
288 |
||||
|
Frequency Hz |
50/60 |
||||||
|
Standards |
|||||||
|
Safety |
IEC 61439-2, МЕК 62196-2; DSTU EN 61851-1:2019; DSTU EN 61851-22:2002; DSTU EN 61851-23:2014; DSTU EN 61851-24:2015; DSTU EN 61439-1:2016 |
||||||
|
EMV |
EN 61000-6-2: 2005; EN 61000-6-3: 2007 + A1: 2011 |
||||||
|
CHAdeMO |
Рев. 0.9.1, рев.1.0.1 (compatible) plug JEVS G105 |
||||||
|
GB/T |
GBT18487 |
||||||
|
Charging ports |
|||||||
|
Charging ports (max., pcs.) |
4* (4DC, 3DC+1AC, 2DC+2AC) |
||||||
|
DC port |
CCS Combo 2 |
CCS Combo 2 |
GBT |
CHAdeMO |
|||
|
Output voltage, V DC |
150-1000 |
150-1000 |
150-1000 |
150-500 |
|||
|
Output current, А |
500A peak |
500A peak |
300A peak |
125A |
|||
|
Power factor (at 50% load) |
> 0.97 |
||||||
|
Efficiency |
> 94% |
||||||
|
AC port |
socket/cable |
||||||
|
AC port (type) |
Type 1 |
Type 2 |
|||||
|
Maximum output power, kW |
7 |
22 |
|||||
|
Output voltage, V AC |
230 ± 10% |
400 ± 10% |
|||||
|
Output current, A |
0-32 |
0-32 |
|||||
|
Are common |
|||||||
|
Operating temperature, ˚C |
-30 to + 50 |
||||||
|
Storage temperature, ˚C |
-30 to + 50 |
||||||
|
Relative humidity |
5% to 95% (no condensation) |
||||||
|
IP protection class |
IP55 (placement: indoor and outdoor) |
||||||
|
Dimensions size (L x W x H), mm |
800 x 2000 x 800 |
||||||
|
Dimensions max. (L x W x H), mm |
1300 x 2200 x 870 |
||||||
|
Weight, kg |
490 |
||||||
|
Self-consumption power: – in standby mode, W – with anti-condensation heating on, W – with ventilation on, W |
100 600 300 |
||||||
|
Noise level (at full load), dB |
<55 |
||||||
|
Other |
|||||||
|
Internal interface |
OCPP 1.6 |
||||||
|
Authentication/payment systems |
RFID, mobile applications; calculation by time/kW (according to the customer’s wishes) |
||||||
|
Compound |
Ethernet / UMTS (3G modem) / LTE 4G/Wi-Fi |
||||||
|
Compatibility |
According to DSTU EN 61851-1:2014 |
||||||
|
Precautionary measures |
|||||||
|
DC side (output) |
Insulation monitoring |
||||||
|
AC side (output) |
Residual current device (RCD) |
||||||